Oxygen is usually present where corrosion takes place. What would happen to steel in an area, where no oxygen exists?
Will corrode in the normal way.
A different form of corrosion could take place.
It will be protected against corrosion.
What are the most important parameters to be observed during application of a convertible coating system?
The absolute number of days, stated on over-coating intervals to be observed.
The over-coating interval being a product of time and air temperature to be observed.
The over-coating interval being a product of time and steel temperature to be observed.
To observe the weather condition during the period.
What are the most important things to monitor when inspecting coating conditions?
Inspect the areas, only where coating has broken down.
Inspect a typical area, where you can access easily.
Inspect both intact and corroded areas, and also inspect angles, corners, behind bars etc.
Inspect suspected areas only.
What determines the rate, at which the corrosion process of steel proceeds?
The amount of oxygen present and the ambient temperature.
The conductivity of the electrolyte, ambient temperature, amount of oxygen present and the relative sizes of cathodic and anodic areas.
The relative sizes of cathodic and anodic areas, and the conductivity of electrolyte.
The conductivity of the electrolyte.
What is the key role, that you carry out when evaluating steel condition?
You are there to decide the next repair action.
You need to be able to assess the condition, and be able to report that condition accurately (so that decisions can be made based on your report).
You are there to understand, what has happened to the steel.
You are there to approve the work done.
What is the main single factor, which affects the cost of preparation and application to difficult vessel areas?
The specialised labour required.
The cost of access to an area.
What should be observed during application of convertible coating systems in cold weather?
That sufficient curing time, above the minimum curing temperature of the coating, is allowed prior to application of the next coat.
That sufficient curing time is allowed prior to application of the next coat.
The correct ambient temperature.
What type of corrosion on a coated deck-area would you most worry about?
1 % localised pitting corrosion.
Localised damage corrosion.
Would cargo remnants, e. g. coal mixed with water, affect the corrosion rate?
The water in contact with the sulphur in the coal will form an active electrolyte, which will tend to accelerate the corrosion process.
This would have none or little effect on the corrosion rate.
This would have no effect if the water present is fresh water.
There will be no corrosion.
A large area of exposed deck is to be blasted to an agreed standard of SA2 before application of an epoxy paint system. In the vicinity of some pipes, where difficult access means that the blasting is not able to remove all the corrosion. What do you do?
Discuss the various options with the contractor.
Accept the blasted areas and go ahead with painting.
Reject the whole blasted areas, until blasting is redone to the correct SA2 standard.
During a dry-dock paint application why only check dft’s on spot blasted areas, how do you check the antifouling thickness?
You can also check dft’s on non-blasted areas.
You check the wet film of each coat, at various parts of the hull.
Spot blasted areas are the only areas coated from the steel surface upwards – you control the antifouling thickness by controlling the distribution.
Paint is applied to a deck in the morning. Each morning the air temperature is 7 °C. In early afternoon the temperature of the air rises to 23 °C. You are told, that the maximum overcoating time for the paint coating is 36 hours at 20 °C and 48 hours at 10 °C. In this case, what maximum overcoating time do you allow?
You consult the Technical data sheet for the paint.
You consult the paint supplier’s representative.
Please select the advantages from the following list of advantages and disadvantages of “Dry Abrasive Blasting” method:
Please select the advantages from the following list of advantages and disadvantages of “Hydro blasting” method:
Please select the advantages from the following list of advantages and disadvantages of “Wet Abrasive Blasting (Slurry blasting)” method:
The main contaminants in a Marine environment are SALT, CORROSION, MOISTURE, OIL & GREASE, DUST AND HULL FOULING. What is the most efficient method of removing HULL FOULING?
Low Pressure High Volume Water Washing.
High Pressure Water Washing.
Scraping to remove the fouling.
The wet film of paint, which is applied, bears a direct relationship to the final dry film thickness of the coating. Taking wet film measurements can be very important. Why is it important to take these measurements as quickly as possible?
To avoid the fresh coat softening the coats underneath leading to possible wrong readings.
So that the painter is disturbed as little as possible.
To obtain as close a reading to the actual wet film as possible.
What is the minimum number of degrees centigrade the steel temperature must be above the dew point before paint application?
What piece of equipment would be the most effective in removing corrosion from difficult corners or angled areas?
When using Airless Spray equipment, what are the 3 most important safety rules to observe?
Which are the 3 factors, which influence the length of time from finishing an antifouling coating to the flooding of the dry-dock?
Which are the 3 factors, which help contribute to correct performance of a paint system?
Which of the following statements best describes one of the main advantages of Hydro blasting with fresh water as opposed to Dry Abrasive Blasting?
Produces a Surface Profile to aid adhesion of coatings to the surface.
Only requires air power for operation.
As well as removing corrosion products it also removes salt contamination.
The prepared surfaces will flash rust.
Why is fresh water washing important before commencing paint application?
Why should the use of long lines be avoided, if possible, during spray application?
Risk of paint curing in the line.
Safety risks due to increased length.