The test consists of 80 random questions.
Total questions on this topic: 110
To make a “call-request” one should:
Select the telex in on-line position.
Select the ID of the NCS.
Select the telex in off-line position.
Which of the given options characterizes a 2-stroke diesel engine?
The piston always has a short skirt.
A 2-stroke engine always has 2 or more turbochargers.
A 2-stroke engine has an air inlet valve in the cylinder cover.
A 2-stroke engine completes a full cycle every revolution.
The main engine is running steady with an average exhaust gas temperature of approximately 350 °C. What would be a typical alarm/slow down setting for the cylinder exhaust gas temperature deviation from the average?
One of the Main Engine cooling pumps is down for maintenance. The rest of the cooling pumps are operating near full capacity with minimum margins on the maximum temperature limit. What should be the correct action to take with regard to UMS operation?
Operate the engine room on manual mode until the maintenance is completed and the cooling pump is operational and switched to stand-by mode.
Arrange with a rating “on watch” in the engine room for the UMS period.
Arrange frequent checks of the condition during the night otherwise operate in normal UMS-mode.
When starting three phase induction motors which of the following starting methods will immediately apply rated voltage to the machine?
Why is it necessary to have an effective ballast water management plan which includes provision for changing out ballast in open water rather than discharging ballast in coastal waters?
To allow ballast tank inspections to be carried out during ballast passage.
To keep the ballast water fresh in the ballast tanks during long voyages.
To ensure that ballast tanks are always pressed up during a ballast voyage to avoid free surface effects.
To avoid the introduction of non-indigenous species of marine life from one area to another.
The majority of marine diesel engines operate with either a pulse or a constant pressure turbocharging system. What is the main difference between these two systems?
Pulse systems always have a turbocharger for each group of three cylinders.
Pulse systems have all of the cylinder exhausts connected to a common large exhaust gas manifold.
Constant pressure systems only ever have a single turbocharger irrespective of the number of cylinders on the engine.
Constant pressure systems have all engine cylinder exhaust connected to a common large exhaust gas manifold.
Give the meaning of the following symbol:
Rescue boat with waterproof canopy.
Which statement about the use of profiling onboard a ship is true?
A random selection process must be established.
Only visitors can be profiled.
Detection equipment can be used in place of profiling.
Profilers need at least half an hour to gather the information they need.
How is the prime mover load normally kept to a minimum when starting up an electric driven reciprocating type air compressor?
By using an unloading device to keep the compressor suction valves open until the machine is up to speed.
By using an unloading device to keep the compressor delivery valves open until the machine is up to speed.
By keeping the main discharge valve closed until the machine is up to speed.
By keeping the second stage drain valve open until the machine is up to speed.
This circuit consists of two capacitors, C(1) = 6 μF and C(2) = 12 μF, in series. Calculate the equivalent C(S) of the two capacitors.
A vessel is scheduled to enter a SECA during a forthcoming voyage? What additional considerations must a Chief Engineer take into account when planning for this voyage?
That the incinerator is shut down for the duration of the time the vessel is in the SECA.
That there is sufficient room in the bilge holding tank to ensure no discharges of machinery space bilges takes place while the vessel is in the SECA.
The availability of low sulphur fuel and the change over time required to ensure the system is clear of normal fuel prior to entry into the SECA.
That all garbage is fully disposed of prior to entry into the SECA and suitable arrangements are made for retention while in the SECA.
A High Breaking Capacity fuse found in a Main High Voltage Switchboard will typically have fault level rating of?
What is a steering wheel?
A helm used to steer the ship.
A drum for heaving of ropes.
Another name for a lifebuoy.
This circuit consists of two resistances, R1 = 6 ohm and R2 = 12 ohm, connected in series. Calculate the equivalent resistance R(S) of the two resistances.
Why is it important to reduce the diesel engine load during in service water washing of the turbocharger gas side?
To prevent damage to the turbine blades.
To reduce the air pressure to the water dosage pot.
To prevent overload of the turbocharger bearings.
To avoid cold corrosion of exhaust system.
In the event of a diesel engine crankcase explosion which of the safety devices fitted to the engine is designed to minimise the risk of a secondary explosion?
Main bearing temperature monitoring equipment.
Crankcase extraction fan.
Crankcase oil mist detector.
Crankcase relief valves/doors.
How many rescue boats should be provided on ro-ro passenger ships of 500 gross tons and above?
Two, and at least one of the rescue boats shall be a Fast Rescue Boat.
None providing the ship has lifeboats.
Two Fast Rescue Boats, one on each side of the ship.
A 3-phase cage rotor induction motor requires protection by a time delay overload trip. What is the reason for this?
It will tolerate fault conditions during start up.
It will allow for inrush current or motor specific faults.
How will continuous low load operation influence the time between overhauls, tbo, for the cylinder covers and associated valves of a 4-stroke diesel engine?
Reduce the time between overhauls due to increased fouling.
Increase the time between overhauls since fuel injectors work better at low load so combustion will be improved and the maintenance will be reduced.
No influence at all, the required overhauls are unaffected by operating load.
Increase the time between overhauls since the engine is not working as hard.
Falls used in launching shall be turned end for end at an interval of not more than X months and to be renewed not later than every Y years, where the intervals are:
The circuit consists of two inductors, L(1) = 6 H and L(2) = 12 H, connected in parallel. Calculate the equivalent L(S) of the two inductors:
The operation of a diesel engine is controlled by a mechanical-hydraulic, compensated speed sensing governor. How will the governor control be affected if the compensation needle valve is closed in and the engine load changes?
Engine speed control will be sluggish.
The governor will hunt resulting in erratic engine speed control.
A change in load will not affect a speed sensing governor.
What effect would turbulent fluid flow through a heat exchanger have on the efficiency of the heat transfer?
Turbulent fluid flow generally increases heat transfer efficiency.
It cannot be determined since it is not possible to generate turbulent fluid flow through a heat exchanger.
Turbulent fluid flow generally reduces heat transfer efficiency.
Heat transfer efficiency is not affected by the type of fluid flow through the heat exchanger.
A combustible gas indicator of the catalytic filament type is used to check the atmosphere in an enclosed space onboard ship. When taking readings in a fuel tank which has been emptied for cleaning the meter reading initially rises and then falls back to zero. What is the likely defect, if any, in the instrument when this type of behaviour is displayed?
The sampling pump is faulty.
The filament is contaminated due to too high a concentration of hydrocarbons.
The filament has burnt out.
What is polymerisation?
The process by which unsaturated chemical compounds are heated under pressure, causing the molecules to react with each other and form larger molecules.
The process by which the molecules in unsaturated chemical compounds react with each other during cooling, forming larger molecules.
The process by which saturated chemical compounds are heated under pressure, causing the molecules to react with each other and form smaller molecules.
The process by which saturated chemical compounds react as pressure is released during heating, causing the molecules to react with each other and form larger compounds.
HEL-H is the abbreviation of a heavy helicopter radius of action for rescue purposes. What do you think the radius and evacuating capacity of the helicopter is?
100 nm and capacity for evacuating more than 10 persons.
500 nm and capacity for evacuating more than 25 persons.
200 nm and capacity for evacuating more then 15 persons.
A diesel engine is operating with retarded fuel timing resulting in increased exhaust gas temperatures. How would you expect this to affect the turbocharger?
Increased turbocharger revolutions.
Reduced air and gas temperature after turbocharger.
Decreased turbocharger revolutions.
The turbocharger would operate normally.
When will a ro-ro vessel pitch heavily?
When wave lengths are equal to the ship’s length.
When wave lengths are equal to half the ship’s length.
When wave lengths are equal to twice the ship’s length.
On board a DSC-call is to be made in case of an OBS. Choose the category:
Which ideal heat engine cycle is the vapour-compression refrigeration system based on?
The reversed Carnot cycle.
What is the required pressure when testing parts of the oil transfer system (hoses, loading arms etc.) if the test is to satisfy US Coast Guard regulations?
Test pressure equal to 1,75 times the maximum allowable working pressure.
Test pressure equal to 1,25 times the maximum allowable working pressure.
Test pressure equal to 1,5 times the maximum allowable working pressure.
Test pressure equal to the maximum allowable working pressure.
Some fuel oil and lubricating oil separators have a facility to control the back pressure of the clean oil outlet during start up and operation. What is the purpose of this control function?
To control the amount of fuel passing through the separator.
To help to maintain the oil/water interface at the correct position.
To assist in discharging the bowl contents during the sludge cycle.
To reduce the amount of sealing water required during operation.
What should the expansion valve superheat setting be in order to get the best possible efficiency from a refrigerator evaporator?
The water cooling space on a turbocharger is damaged and there is no spare casing. The cooling water must be shut off. Which option would you take to keep the risk of further damage to a minimum?
Dismantle the rotor and assemble the sealing plates.
Run the engine at a lower speed.
Make no modifications, but tell the duty engineer to pay special attention for abnormalities.
Cool the turbocharger by means of air.
The engine turns over normally when starting air is supplied but does not fire even though normal starting rpm is achieved. What could be the probable cause to this?
Air in the fuel oil system.
The turning gear interlock has operated.
The turbocharger has not run up to normal full speed.
The lubricating oil temperature is low.
According to 33 CFR 156, oil tankers trading in US waters are required to test and document the testing of cargo transfer hoses and transfer pipe system. What is the minimum requirement when testing these components?
That no leakage occurs under static liquid pressure of at least 1,5 times the maximum allowable working pressure.
That no leakage occurs under dynamic fluid pressure of less than 1,5 times the maximum allowable working pressure.
That no leakage occurs at the nominal anticipated working pressure.
That no leakage occurs under static liquid pressure of at least 1,25 times the maximum allowable working pressure.
When starting up an aerobic type sewage unit for the first time, of after manual cleaning, how should the bacterial process be initiated?
By adding an activating agent to the inflowing sewage.
By bypassing the grey water inflow and operating only with black water.
By shutting off the air flow.
By filling the unit with sewage and bubbling air through it for 48 hours prior to starting the discharge pump.
In the case when the temperature of the ambient air is equal to 10 °C and the wind is blowing at a speed of 10 m/sec the shipwrecked person must consider that the effect of air on his body is equivalent to that of an air whose temperature would be approximately:
Maintenance is to be carried out on a diesel engine. How long after stopping the engine should the cooling water and lubricating oil be kept circulating in order to avoid any undue thermal stress from residual heat?
10 minutes is sufficient.
What do you understand by the term Maximum Continuous Rating, MCR, of a diesel engine?
The maximum speed that the engine can operate at continuously.
The maximum load that the engine can operate at continuously.
The maximum cylinder pressure that the engine can operate at continuously.
The maximum charge air pressure that the engine can operate at continuously.
Which one of the listed requirements regarding fire protected lifeboats do not correspond to present regulations? Water spray systems shall:
Have separate draining pumps of sufficient capacity.
Be arranged for flushing with fresh water and allowing complete draining.
Protect the occupants through a continuous oil fire for a period of not less than 8 minutes.
Have means for “turn on/turn off” the flow of water over the exterior of the lifeboat.
Which class of emission is used for FEC NBDP transmissions?
When bunkering through the port side of the bunker manifold what action should be taken with the valves on the starboard side of the manifold prior to bunkering operations commencing?
Blank flanges should be fitted to the closed starboard side manifold valves.
Just fit the blank flanges then it doesn’t matter if the valves are closed or not.
The blank flanges should be removed from the starboard side manifold valves to check for any leakage past the closed valves.
Just check that the valves are closed.
When trying to reverse a large slow speed diesel engine in the astern direction it cannot be turned on air even though it will start in the ahead direction. What is the likely cause of this problem?
The reversing servo for the fuel pumps has stuck in the ahead position.
One of the cylinder air start valves has stuck open.
The start is blocked because the air distributor has not moved to the astern position.
Which of the following terms is used to describe a thermodynamic process in which no heat transfer into or out of the system occurs?
When starting air is applied to a diesel engine the engine fails to turn over but is seen to oscillate back and forth. What is the most likely cause of this problem?
Starting air pressure is too low.
One or more cylinder air start valves are stuck open.
An interlock is blocking the air to the starting air distributor.
The automatic valve has failed to open.
Most fuel oil separators working on the centrifuge principle have an automatic start up and sludging facility. Which of the following actions would you expect to occur first during the start up sequence?
Increase the scavenge air temperature to minimise the condensate from the charge air cooler.
Reduce the engine load to minimise condensate from the air cooler.
Ensure that condensate drains from the water separator are monitored and operating correctly.
Decrease the scavenge air temperature to minimise the condensate from the charge air cooler.
Which of the following symptoms would indicate that the filter drier in a refrigeration circuit has become blocked?
A large temperature drop across the drier.
A pressure rise before the drier.
A hammering noise from the drier.
The turbocharger on a diesel engine is surging. Which one of the following options would be the most likely cause?
The lubrication oil pump is malfunctioning.
Dirty rotor blades and nozzle ring.
Worn out bearings on the turbocharger.
Dirty scavenging air cooler on the air side.
When lashing general cargoes why are short lashings preferred to long ones?
Because they are more easily tightened and held in tension.
Because long lashings are more prone to vibration.
Because some of the ship’s lashing points may not be designed to hold long lashings.
Because the safe working load of lashing materials decrease with length.
A water heating system with automatic temperature control uses steam as the heating medium and the temperature is controlled by a pneumatically operated valve? What would be an acceptable start up procedure of the system from cold state?
Start the system up in manual mode and gradually increase the controller output signal until the temperature reaches the required value before changing over to automatic control.
Start with the control valve in manual and use the hand jack to gradually increase the temperature by throttling the steam flow before changing to pneumatic control.
Start the system up in automatic mode with normal set point but with the steam supply to the control valve manually throttled in.
What contributes most to rust formation on vehicles/Ro-Ro units?
Cargo hold ventilation systems and associated ducting.
Pipes passing through cargo holds.
Hydraulic units in cargo holds.
The image shows an indicator diagram taken from a diesel engine cylinder. Which of the following options is the action most likely to identify the fault?
Check that the fuel temperature and viscosity are correct.
Check if the fuel injection valve is partly blocked.
Check if the fuel pump injection is too early, or fuel pump lead is too great, for that cylinder.
Which of the following options would be a typical differential pressure setting for a main engine slow down in the event of jacket cooling water system low flow?
What is the correct name of the tool shown in the sketch?
What is the colour of the smoke signal used by life-saving stations or rescue units indicating that distress signals are observed in daylight?
According to SOLAS Regulation all dedicated seawater ballast tanks on oil tankers shall have an efficient corrosion prevention system such as hard protective coatings or equivalent. With regard to coatings do SOLAS set any requirement to colour?
Preferably light red colour.
Telephones are being used to communicate between personnel onboard and ashore during a bunkering operation. What instruction would you give to ship personnel regarding action to take in the event of failure of the telephone communication during the operation?
Use a crewmember as a messenger between personnel involved in the operation.
Call the electrician, and get him to repair the telephone while the bunkering operation continues.
Slow down the bunkering rate until alternative reliable communications are established.
Stop the bunkering until alternative reliable communications are established.
During mooring operations which is the safe place to be in?
Outside the colored zone.
Behind the “point of restraint” but inside the zone.
Between the “point of break” and the “point of restraint”.
Where ever you feel safe.
You are in charge of a night bunkering operation. The delivery rate from the supplier is high and you are filling six tanks simultaneously. You lose track of the progress of the operation and feel that you are losing control of the situation. What action should you take?
Prepare yourself and the crew for an overflow.
Open more tanks to slow down the filling rate of individual tanks.
Stop bunkering, and establish facts, before bunkering is resumed.
Request a reduction in the delivery rate to try and gain some time.
Which is the “Fairlead”, in the figure?
The Fairlead is indicated by C, in the figure.
The Fairlead is indicated by D, in the figure.
The Fairlead is indicated by B, in the figure.
The Fairlead is indicated by A, in the figure.
The cold room temperature is almost at the cut out point in a vapour-compression refrigeration system. What should the refrigerant state be just after the evaporator if the system is correctly set up?
Sub-cooled liquid at low pressure.
Slightly superheated low pressure gas.
Cold liquid at high pressure.
Wet vapour at high pressure.
There are many types of pumps fitted onboard ship which an engine room rating may be required to assist with the maintenance of. Which type of pump is shown in the illustration?
What are we seeing here?
A sailing vessel less than 20 metres in length, displaying the optional combined lantern in lieu of standard sailing lights, seen head on.
A sailing vessel, seen from astern, where the edges of her sidelights are both visible.
A sailing vessel of less than 10 metres in length, displaying the mandatory combined lantern in lieu of sailing lights, seen head-on.
A sailing vessel, at anchor.
Prior to the lunch break, the Engineer on Duty observes that the operating generator set has an output of 90 %. With regard to operation of the generator, what is the – most important – assumption(s) for him to check before switching to UMS-mode?
Visually checking the auxiliary engine that there are no leaks or other obvious operating failures.
That a secondary auxiliary set is switched to automatic standby mode.
All parameters as listed under the other alternatives.
That all operating parameters of the generator set in operation are normal (e. g. exhaust temp, lube oil pressure, cooling water temperature etc).
Maintenance is to be carried out on a diesel engine. How long after stopping the engine should the cooling water and lubricating oil be kept circulating in order to avoid any undue thermal stress from residual heat?
10 minutes is sufficient.
Which one of the following items has to be included in an abandon ship drill according to SOLAS regulations?
Manoeuvring the lifeboat in the water.
Launching and recovery of a survival craft.
Starting and operating radio life-saving appliances.
Checking that life-jackets are correctly donned.
A compressed air supply system has two automatically controlled air compressors. When demand is high both compressors are needed to meet the delivery requirements. What is the best method for controlling the compressors to meet a varying, but intermittent demand?
One compressor running continuously with the other on standby.
Start and stop of the compressors controlled by timer switches.
Continuous running of both compressors and the use of unloading devices.
Sequential start initiated by pressure switches set at different switching pressures.
According to the rules of GMDSS vessels are equipped with certain radio-communication devices depending on:
During crude oil washing of No: 1C tank the duty deck officer reports that the oxygen reading in the tank is 9 %. What should you do?
Stop the washing process and not resume until the oxygen content in the tank below 8 %.
Carry on and ask the engineers to check the inert gas system.
Stop the washing process and not resume until the oxygen content in the tank is below 2 %.
Carry on with the washing as the reading is below 11 %.
When planning bunkering operations it is preferable to arrange for the new fuel to be bunkered into empty or nearly empty tanks whenever possible. What is the main reason for this?
So that the sulphur content of each fuel is known.
To minimise the risk of microbial contamination of the fuel.
To make it easier to calculate the quantity of fuel taken onboard.
To minimise the risk of incompatibility between different fuels.
What types of fire extinguishers shall be used in the engine room?
Fire extinguishers equipped for powder or CO2 only.
Any fire extinguisher with a weight of less than 100 lbs.
Fire extinguishers filled with fresh water only.
Fire extinguishers of the handy-size types only.
How often should the lifeboat wire falls be turned and renewed?
Turned at intervals of not more than 30 months and renewed every 5 years.
Turned every 2 years and renewed every 4 years.
Turned every 30 months and needs only to be renewed if the wire is in poor condition.
Consider a vessel with a 6 cylinder main diesel engine operating with one cylinder out of operation. What would you expect to be the approximate maximum reduced engine load to allow safe emergency operation in this condition?
Approximately 50 % of MCR.
Approximately 70 % of MCR.
Approximately 30 % of MCR.
Approximately 90 % of MCR.
When is it compulsory to use emergency wires/fire wires for mooring the vessel?
During loading/discharging of persistent/non-persistent oil.
At all terminals where tugs are available.
When requested by the terminal staff.
At the terminals in Canada and USA.
Most fuel oil separators working on the centrifuge principle have an automatic start up and sludging facility. Which of the following actions would you expect to occur first during the start up sequence?
Operating water supplied to bowl to close it.
Sealing water supplied to bowl to prevent carry over.
Fuel oil supplied to bowl to fill it.
Operating water drained from bowl to open it.
The piston rod of a large two stroke diesel engine has been damaged and is heavily scored in way of the piston rod gland (stuffing box). It has been decided that it is economically viable to recondition the rod at a shoreside facility. Select, from the options given, the most suitable repair method that should be used?
Recondition the rod by surface grinding and build up using plasma spraying with metal similar to the original.
Recondition the rod by build up using electric arc welding and surface grinding.
Recondition the rod by machining away the score marks and fit undersize rings to the stuffing box.
Which ideal heat engine cycle is the vapour-compression refrigeration system based on?
The reversed Carnot cycle.
Which one of the options given is the most likely cause of a diesel engine failing to turn on air when the start signal is initiated?
An interlock or blocking device in the remote starting system is operating.
Start air compressor has cut out due to sufficient pressure in system.
Slight leakage at the indicator cocks.
Auxiliary blower is operating.