Тест складається із 80 випадкових питань.
Усього питань на цю тему: 147
What is the meaning of “make fast”?
What is meant by the term “feel over sequence” as applied to diesel engine operation following replacement of a crankshaft bearing?
Stopping the engine to check the bearing temperature after a short period of operation and repeating this procedure at increasing running intervals.
Running the engine at low load and gradually increasing the load over a period of 12 hours.
Stop the engine after 2 hours running to check the bearing temperature by running the hand over it.
What is the most important task after carrying out any major overhaul on a diesel engine?
Start the auxiliary blower to ventilate the engine so that it has sufficient fresh air for starting.
Start the engine to check the direction of rotation.
A thorough check inside the engine to make sure all tools and cleaning rags have been removed.
Repair any damaged paint work on the engine.
Which of the options represents the best action to take when an item of machinery, which normally operates in automatic mode, is operated in “manual” mode?
Keep the Chief Engineer informed of machines performance on an hourly basis.
Have someone permanently stationed at the machine in case of an operational problem.
Monitor the operation of the machinery on a frequent basis.
Change over all other machinery to manual mode of operation.
What is the correct name of the tool shown in the illustration?
What would the First Engineer require?
The First Engineer would require the Chief Officer to keep him advised of bilge soundings.
The First Engineer would require the Fitter to check the carbon dioxide fire-fighting equipment.
The First Engineer would require cleaning of the feed water tank.
The First Engineer would require an inspection of the heating coils.
Personnel in a high voltage switchroom and smell rotten eggs. What may this indicate?
Arcing at badly coupled bus bars.
Problems with a vacuum circuit breaker.
Problems with a gas (SF6) circuit breaker.
What acton is required if the crankcase relief valve on an air compressor is operating and emitting an air and oil mixture?
Increase the lift pressure of the relief valve.
Overhaul the compressor unit.
Increase the flow of cooling water to the compressor and intercooler.
Place a drip can beneath the valve to collect any escaping oil.
What type of component does this graphical symbol illustrate?
Pressure-reducing regulator.
What is the best method to use to remove heavy scale and fouling from the plates of a heat exchanger?
Use high-pressure cleaner with abrasive additives.
Soak the plates in recommended cleaning solution and then use a soft brush or pressure cleaner.
Use wire-brush metal scrapers and chipping guns.
What is the correct name of the part highlighted in the illustration?
When you join a new ship, how are you informed about safety rules, alarm instructions and your own duties in case of an emergency?
By folder distributed to each crewmember.
By muster list exhibited in conspicuous places.
By alarm instructions in all crew cabins.
By oral instructions by the Captain.
What would be the correct form of response to the question: “What kind of assistance do you require?”
The correct form of response would be: “There is a fire onboard my vessel”.
The correct form of response would be: “My vessel has a fire in the accommodation and we require fire-fighting assistance”.
The correct form of response would be: “I need help on board with a fire and the smoke is very toxic”.
The correct form of response would be: “I need help as soon as possible”.
During maintenance of a piston rod stuffing box on a large, slow speed diesel engine it is usual to measure the butt gaps between the sealing ring and scrapper ring segments. What would be the effect of these gaps being too small?
If the gaps are too small the rings could scope the piston rod.
If the gaps are too small they could close due to the radial wear of the rings before the next scheduled overhaul preventing the rings from contacting the piston rod and sealing it.
If the gaps are too small then the flow of scavenge air through the gland would be reduced and the gland would overheat.
If the gaps were too small then no oil could pass up the piston rod to lubricate the sealing rings.
Personnel in a high voltage switchroom smell ozone. Which of the following is the likely cause?
Air circuit breaker problems.
Arcing at badly connected bus bars.
Vacuum circuit breaker problems.
The correct time to synchronise is usually taken to be when the synchroscope reaches the “5 to 12” position and is rotating slowly clockwise. This to allow for:
Generator phase difference error.
Circuit breaker operating time.
Synchroscope pointer time lag.
During an unmanned period on a UMS vessel the “low water level” alarm for the jacket cooling water system expansion tank activities. What action would you take as duty engineer?
Answer the alarm then block the alarm function for later action and resume unmanned operation.
Answer the alarm then block the alarm and change to manned engineroom condition.
Answer the alarm and adjust the alarm set point for the water level in the expansion tank before resuming unmanned operation.
Answer the alarm, top up the tank and check the system for leakage before resuming unmanned operation.
What is the correct name of the part highlighted in the illustration?
B Class divisions in ships are constructed so that they are capable of preventing the passage of flame to the end of a standard fire test held for:
Which diagram is the symbol for a THYRISTOR?
What cooling medium is normally used to cool the condenser of a fresh water generator?
What are the lists called that give the position and task during a lifeboat drill for all persons on board the ship?
After main power is restored (following a blackout), a timed sequential restart of motor driven auxiliaries is necessary to avoid:
Generator overload due to many motors starting at simultaneously.
Overvoltage due to current surges.
Overloading creating earth faults.
Over-frequency due to overspeed of generator.
For a Nitrite – Borate based cooling water treatment system, what would be considered to be the normal nitrite concentration limits for a correctly dosed system?
3 000 – 4 500 ppm Nitrite.
1 500 – 3 000 ppm Nitrite.
4 500 – 6 000 ppm Nitrite.
For ideal synchronising as the incomer circuit breaker contacts make, the phase angle difference between the incomer e. m. f. and the busbar voltage should be:
What is the approximate content of oxygen in air?
Where would you find out which fire sections are enclosed by “A” or “B” class divisions on a ship?
All the mentioned alternatives.
On the general arrangement plan.
On the Ship’s fire control plans.
An important quantity which is useful in circuit analysis is known as conductance G (Siemens). Which of the formulas A to D expresses the conductance for this circuit?
Under what circumstances would you remove guards and safety devices from machinery?
To allow the shaft to be seen to confirm the machine is running.
When they are rattling and vibrating.
During overhaul and maintenance procedures.
When the safety devices keep stopping the machinery.
This device can detect a package of drugs inside a large delivery of ship’s stores. What is it?
What do you understand by: “Let go the port anchor?”
Let go the port anchor means: slacken the port anchor cable.
Let go the port anchor means: put the port windlass brake in gear.
Let go the port anchor means: put the port windlass brake in gear and lower the anchor.
Let go the port anchor means: open the port windlass brake.
As part of the regular maintenance for a paramagnetic oxygen analyser used for measuring the oxygen content of exhaust gas it is important to keep the sample line filter as clean as possible. Why is this necessary with this type of instrument?
The filter may rupture due to the high pressures generated by the sample pump.
Pressure variations in the sample chamber can cause errors so restrictions must be kept to a minimum.
The pressure drop across the filter may damage the sampling pump.
A high flow rate is required in order to deflect the sensing element.
What is the most important task after carrying out any major overhaul on a diesel engine?
Start the engine to check the direction of rotation.
Repair any damaged paint work on the engine.
A thorough check inside the engine to make sure all tools and cleaning rags have been removed.
Start the auxiliary blower to ventilate the engine so that it has sufficient fresh air for starting.
What function is this operational amplifier circuit performing?
Which of the following voltage levels would be regarded as high voltage likely to be found on a ship?
What do you understand by: Bitter end?
Bitter end means: the end link of an anchor cable that is secured within the chain locker.
Bitter end means: a foul taste at the end of a meal.
Bitter end means: to the very last moment.
Bitter end means: the toggled end of a lifeboat painter.
What is the disadvantage of using chemicals on an oil-spill on the water?
It is difficult to apply the chemicals if the oil drifts away from the ship’s side.
The chemicals make it difficult to remove the oil from the water.
It is difficult to apply chemicals if there is any wind.
The water gets a white colour, which makes it easy to detect the oil-spill.
PT-100 sensors are some times used with 3 or 4 wires. What is the reason for this?
Higher mechanical strength of the cable.
Because of power-consumption.
Higher measuring accuracy.
Which one of the listed requirements regarding the stowage of a survival craft corresponds to present SOLAS regulations? Each survival craft shall be stowed:
In a secure and sheltered position and protected from damage by fire or explosion.
Wherever space is available.
In a state of readiness so that two crew-members can prepare for embarkation and launching in less than 15 minutes.
On the starboard side of the ship.
The responsibility for safety and security rests with everybody on board the vessel. General house-keeping rules should be followed. Which of the listed rules is the most important?
Do not carry lighters or matches when working outdoors.
Always use gloves when using grinding machines.
Keep tools within easy reach during work.
Keep your working area clean and tidy.
Some large slow speed diesel engines have jack bolt arrangements for retaining the main bearing top keep in place rather than the more conventional stud bolts. How does this arrangement affect the maintenance and checking procedures for the tie rods on the engine?
The tie rods should be fully tensioned before the jacking bolts are loaded to avoid overload of the bearing caps and frame structure.
The tie rods and jacking bolts must be tightened simultaneously to avoid excess load on either component.
The jacking bolts should be fully loaded before the tie rods are tensioned to avoid excess loads on the tie rods.
It has no effect since the tie rods and jacking bolts have completely separate functions.
If a refrigeration system contains air, how would you remove it from the system?
Pump the system down to the evaporator and keep the fan running until the evaporator is at ambient temperature and vent off the air from the top of the evaporator.
Stop the compressor and vent the air from the crankcase.
Pump the system down to the condenser, continue cooling water flow until the condenser is at the same temperature as the cooling water and vent off the air from the top of the condenser.
Stop the compressor and undo a pipe coupling at the highest point in the system to vent off the air.
What precautions should be taken, in addition to shutting the main air start valve if work is to be carried out inside the main diesel engine crankcase?
Keep a man posted in the control room to stop anyone who tries to start the engine.
Engage the turning gear and put a notice at each engine control position.
Engage the turning gear, stop the starting air compressors and drain the air receivers.
Engage the turning gear and close every valve on the starting air receivers.
Which of the following instruments is normally part of a control-loop?
The lubricating oil in the bearing housing at the turbine end of a turbocharger gets very dirty after only a few hours in service. What is the most likely reason for this happening?
The wrong type of lubricating oil has been used.
Damaged rotor shaft sealing bushes allowing exhaust gas to leak into the bearing housing.
The turbine end bearing is badly worn.
The lubricating oil filling connection screw cap is missing.
Modern slow speed, two stroke diesel engines often have locating pins or pegs to keep the piston rings in a fixed position. Why is this arrangement used?
The piston ring gaps can be kept in line to control the gas pressure on each of the rings.
The piston rings are more difficult to lubricate because of the slow operating speeds and will wear more quickly if they are allowed to rotate.
It avoids the risk of the ends of the piston rings being forced out by the gas pressure and catching on the scavenge ports.
It ensures the rings cannot be mixed up and that they are fitted in the correct order on the piston.
Vibration analysis is often used as a conditioning monitoring tool onboard ship as part of the approved planned maintenance system. Many vibration measuring instruments are fitted with a harmonic filter/analyser. How would these filters normally be used during vibration measurement on a centrifugal pump?
To block out any noise or vibration from the surrounding engine room.
To generate an audible sound signal at the same frequency and amplitude as the vibration.
To isolate a single frequency of vibration associated with one of the pumps components.
To sum up all the harmonics of a base frequency to give total vibration for all of the pump’s components simultaneously.
Many large slow speed diesel engines operating on heavy fuel oil have a fuel injection system which features Variable Injection Timing. How does this affect engine operation?
VIT increases engine efficiency by automatically maintaining the maximum cylinder pressure over the entire load range.
VIT allows the ship’s engineers to alter the injection timing for each load setting with a simple single adjustment of the fuel rack.
VIT increases engine efficiency by automatically maintaining the maximum cylinder pressure over part of the load range.
It is recommended that every prospective seafarer should, before being employed in a sea-going ship, receive proper training in personal survival techniques. In respect of such training several recommendations are made. Answer the question: “To whom should training in personal survival techniques be given?”
You are starting to get low on water in the lifeboat. What should you do?
Mix sea water with 50 % fresh water.
What is generally considered as the minimum safe time period before opening a crankcase door after the oil mist detector alarm has activated and the engine has been stopped?
After at least 20 minutes.
After at least 5 minutes.
After at least 10 minutes.
What is the correct method to use for fitting a rolling contact bearing, such as a ball bearing, onto a parallel shaft?
Use a hammer and a pipe with the same diameter as the inner bearing ring and knock the bearing onto the shaft.
Use emery cloth on the bearing surface on the shaft.
Use emery cloth on the inner ring (contact surface) of the bearing.
Gently heat the bearing in an oil bath and use a bearing puller to draw it onto the shaft.
Under which circumstances should a sprinkler head of a common fixed sprinkler fire-extinguishing system be activated?
When the smoke density exceeds 12,5 % obscuration per minute, but after the corresponding alarm is acknowledged and assessed at the control panel.
When the temperature is within a range from 68 °C to 79 °C, but after the corresponding alarm is acknowledged and assessed at the control panel.
Automatically, when the temperature is within a range from 68 °C to 79 °C.
Automatically, when the smoke density exceeds 12,5 % obscuration per meter.
How many Radar Transponders (SART) are required to be carried onboard a ship for use in survival crafts?
2, one of which being capable of floating free if the ship sinks.
Two on each side of the ship.
One on each side of the ship.
What is the expansion ratio of the foam produced by the fixed low-expansion foam fire-extinguishing system of an engine room?
Greater than 20 to 1 but less than 50 to 1.
During maintenance work on a main diesel engine the fuel injection valve is found to be jammed in the pocket in the cylinder cover. Which of the procedures given in the options should be followed in order to complete the work?
Wedge a bar between the piston top and the bottom of the injector and use the turning gear to force the injection valve out.
Replace the complete cylinder cover with a spare unit and land the cover with the jammed valve ashore for repair in a specialist workshop.
Remove the cylinder cover and try and drive the injection valve out of the pocket from the underside with a hammer and punch.
With the fuel injection valve retaining nuts removed admit compressed air into the engine cylinder to try and blow the injection valve out of the pocket.
Which of the following is not a principle of heat transfer utilised in an oil fired steam boiler?
How many separate means of escape are provided from each fire zone above the bulkhead deck?
An electrical power emergency source in a ship is required because:
It satisfies the SOLAS requirements for ship safety.
The main diesel generator(s) can be taken out of service for overhaul or repair.
It satisfies the need to be environmentally “friendly”.
The ships total load can be shared between main and emergency generators.
What do you understand by the order: “Move the pilot ladder to the other side?”
Move the pilot ladder to the other side, means: to move the pilot ladder further along nearer to the bow.
Move the pilot ladder to the other side, means: to rig another pilot ladder.
Move the pilot ladder to the other side, means: to change the position of the pilot ladder from the main deck to the fore deck.
Move the pilot ladder to the other side, means: to shift the pilot ladder to the opposite side of the ship.
In a low pressure auxiliary boiler, what would be considered to be the maximum allowable chloride level of the boiler water?
Which component does this graphical symbol illustrate?
Pressure indicator, installed on panel/console.
Pressure indicator, installed locally.
Pressure relief valve, self-contained.
An earth fault exists on the blue line of a 100 A bilge pump circuit. A second earth fault occurs on the yellow line of a 10 A ventilation fan circuit. Both systems are supplied from the ship’s 440 V supply. The likely outcome is that:
A short circuit occurs between earth faults and the ventilation fan fuse blows.
An open circuit occurs between earth fault and both motors trip out.
A short circuit occurs between earth fault and the bilge pump fuse blows.
Both motors trip out on overload.
A mechanical seal, consisting of carbon and ceramic seal rings, is to be fitted to a centrifugal pump shaft. What is the most likely result of not being extremely carefull when fitting this type of seal?
The spring and bellows for the seal can be easily damaged.
The rubber O rings for the seal can be easily damaged.
The seal rings are hard and may score the pump shaft.
The seal rings are brittle and can be easily chipped or damaged.
A ship has a medium speed engine and a controllable pitch propeller propulsion system. What would the propeller pitch normally have to be at to allow starting of the engine?
You are witnessing someone about to faint. What are the symptoms?
The person may be very pale, and pulse is slow at first and weak.
The pulse is very fast and the person is getting cold.
The person starts to talk a lot and seems superactive.
A ship moving through heavy seas is affected by the water presure at the bows causing an effect known as “Panting”. What structure in the forward region of the ship combats the effects of Panting?
Double bottom tanks and floors.
Panting beams and stringers.
Collision bulkhead and deck.
While alongside at a repair berth a new section of seawater pipe has been fabricated in a shoreside workshop from drawings supplied by the vessel. During fitting of the pipe by ship’s engineers it is noted that the pipe is too short leaving a gap of about 8 mm between the flange faces. What action should be taken to remedy this problem?
The pipe should be returned to the shoreside workshop for modification or to be remade to the correct dimensions.
The ships engineer’s should use extra long bolts and pull the flanges together.
The ship’s engineers should fit extra thick joints between the flanges to fill the gap.
The ship’s engineers should manufacture a spacer piece to fit the gap.
Which ships does the ISM code apply to?
All passenger ships, all cargo ships of 500 GRT or above.
A mechanical seal, consisting of carbon and ceramic seal rings, is to be fitted to a centrifugal pump shaft. What is the most likely result of not being extremely careful when fitting this type of seal?
The seal rings are hard and may score the pump shaft.
The spring and bellows for the seal can be easily damaged.
The seal rings are brittle and can be easily chipped or damaged.
The rubber O rings for the seal can be easily damaged.
Why is it important to check the timing of diesel engine cylinder oil lubricators?
To ensure the piston is not covering the lubrication points and blocking the flow of cylinder lubricating oil into the cylinder.
To ensure the correct amount of cylinder lubricating oil is fed into the cylinders.
To ensure cylinder lubricating oil enters the cylinders when the piston is in the required position.
To avoid excess pressure in the cylinder lubrication system.
With regard to radar, what would be a correct form of response to the question: “What range scale are you using?”
The correct form of response would be: “I am using the 12 mile range scale”.
The correct form of response would be: “I am using the largest range scale”.
The correct form of response would be: “I am using the 10 cm radar”.
The correct form of response would be: “I am using the 3 cm radar”.
It is common practice to connect a resistor over an alarm contact (see diagram) in many applications. Why is this connection used?
To monitor the cable/wires for break.
To stabilise power consumption.
To avoid sparks on the contacts when opening and closing.
Enable measuring the total resistance of the circuit.
On finding a person apparently unconscious in a High Voltage switch room, which of the following should be done?
Raise alarm then drag the victim clear so that they cannot reach live parts while receiving aid.
Check if the victim is in contact with live parts and if not apply first aid.
Raise alarm, identify means of isolation and apply before approaching victim.
Trip all breakers and approach victim.
An earth fault exists on the blue line of a 100 A bilge pump circuit. A second earth fault occurs on the yellow line of a 10 A ventilation fan circuit. The likely outcome is that:
Both motors trip out on overload.
A short circuit occurs between earth faults and the ventilation fan fuse blows.
A short circuit occurs between earth fault and the bilge pump fuse blows.
An open circuit occurs between earth fault and both motors trip out.
What is the correct name of the part highlighted in the illustration?
What is the correct name of the tool shown in the illustration?
A section of seawater pipe has been removed for maintenance. When refitting the pipe after completing the work the bolt holes in the flanges are found to be misaligned. What procedure should be followed to finish the work?
Adjacent pipework should be slackened off to allow the pipe to be aligned. Any incorrectly positioned brackets should be adjusted after the pipe is refitted.
Use a chain block to pull the pipe flanges into alignment and leave it in place after the bolts are fitted to avoid overstressing the bolts.
Use wooden wedges to force and hold the pipe into the correct position and then fit the bolts.
Force the pipe into position and then hammer the bolts into the holes to hold the pipe flanges into alignment.
What is the ideal working temperature for physical work?
Many large slow speed diesel engines operating on heavy fuel oil have a fuel injection system which features Variable Injection Timing. How does this affect engine operation?
VIT increases engine efficiency by automatically maintaining the maximum cylinder pressure over the entire load range.
VIT increases engine efficiency by automatically maintaining the maximum cylinder pressure over part of the load range.
VIT improves engine operation by automatically controlling the start of fuel injection when it detects a poor quality fuel.
VIT allows the ship’s engineers to alter the injection timing for each load setting with a simple single adjustment of the fuel rack.