When in-service testing a hose used for cargo transfer on an oil tanker (and for which the elongation of the hose assembly when new was greater than 2,5 %), the maximum permitted elongation before the hose must be withdrawn from service should be:
Correct answer:
Not more than 1,5 times the temporary elongation measured when the hose assembly was new, as documented in the manufacturer’s certificate.Your Answer:
Not more than 1,5 times the temporary elongation measured at the previous in-service test, as documented in the ship’s annual test record.