Тест по Doppler log (CES v5.0)

Результаты прохождения теста

Ваш результат: 100%
Сохранить в моем резюме
Правильные ответы:
1

Aerated water can affect a Doppler log. Which one of the options is the most likely to produce aerated water?

Ваш ответ правильный:

The wake caused by the other ships propellers.
2

Select the option, which correctly completes the following statement: “If undisturbed reverberation measurement in shallow water is not possible, the system automatically switches to…”:

Ваш ответ правильный:

Bottom track.
3

Select from the options given six factors, that are likely to affect a Doppler log system:

Ваш ответ правильный:

Density differences in water.; Loss of signal or weak signal.; Aerated water.; Loss of bottom track.; Loss of water track.; Orientation of the transducer.
4

Which mode is the most suitable to use if the primary function of the connected ARPA is traffic surveillance?

Ваш ответ правильный:

Water track.
5

Which one of the following statement depends on the “Janus configuration”?

Ваш ответ правильный:

Small errors due to trim, roll and pitch.
6

Which one of the modes given in the options should be used when the Doppler log is connected to an ARPA-radar, which is primarily used for traffic surveillance (according to IMO-rules)?

Ваш ответ правильный:

Water track.
7

Which one of the modes given in the options should be used, when the Doppler log is connected to an autopilot with track keeping functions?

Ваш ответ правильный:

Bottom track.
8

Which one of the options identifies when the Doppler log would normally be switched off?

Ваш ответ правильный:

During dry-docking.
9

Which one of the options is the most likely reason, that a Doppler log’s operation might be disturbed during docking operations?

Ваш ответ правильный:

Due to aerated water from the backwash from own propeller.
10

Which one of the options is the type of measurement used by the Doppler log?

Ваш ответ правильный:

Frequency measurement.