During maintenance of a pneumatically operated, diaphragm actuated control valve the diaphragm is found to be split. Select, from the options given, a suitable material to use to make a temporary replacement if there is no spare diaphragm available.
Правильный ответ:
Natural rubber sheet of approximately the same thickness and elasticity as the original diaphragm material.Ваш ответ:
Cotton reinforced rubber insertion sheet of smaller thickness but similar strength as the original diaphragm material.