Der Test besteht aus 80 zufälligen Fragen.
Gesamtzahl der Fragen zu diesem Thema: 82
In which two ways can a Framo cargo pump be started manually?
If adjustment to an individual pump speed is required, how should it be applied?
By adjusting the individual pump hydraulic pressure.
By throttling the cargo pump discharge valve.
By regulating the main system hydraulic pressure.
By throttling the manifold valve.
After discharge of a cargo of acid and following the purging of the cofferdam, which of the following procedures is recommended?
Circulate fresh water through the cofferdam.
Repeat the purging with a higher pressure to break away any blockages.
Perform a full overhaul on the pump.
Carry out an analysis of the hydraulic oil supply.
What is the recommended operating range for the temperature of the hydraulic oil?
What procedure is recommended after an acid cargo has been discharged and the cofferdam has been purged?
Circulate fresh water through the cofferdam.
Report the result of the purging immediately to Framo.
What must be tended while foot samples are being loaded?
The Framo pump control panel.
The cargo pump discharge valve.
The hydraulic system pressure controller.
What term is applied to the testing process used to check for any leakage past the seals in the cargo pump?
If a tank that previously contained Sulphuric Acid cannot be cleaned immediately after discharge, what should be done with that tank?
Enough water should be put in the sump to submerse the impeller.
It should be thoroughly ventilated.
It should be circulated with a caustic solution for a minimum of 2 cycles with the tank cleaning machines.
When a cargo pump is started, at which hydraulic pressure should it initially be run and for how long before it is increased?
40-50 bar for a minimum of 1 minute.
120 bar for a minimum of 1 minute.
75-100 bar for approximately 2 minutes.
15-20 bar for approximately 3-5 minutes.
When preparing for the carriage of molasses, which liquid is added to the pump cofferdam?
Which process is used to detect any leakage of cargo or hydraulic oil into the cofferdam?
How does purging assist the ship’s personnel? Select all applicable answers:
Which of the following acids is considered to be the most corrosive towards stainless steel?
Once the cargo pump has been run initially and the pressure is then adjusted, to what level is it increased?
Until it is above the cargo manifold pressure.
To a level at least 75 % of the final planned discharge pressure.
By an additional 50 % above the initial level.
What is the maximum recommended duration for which live steam should be applied during tank cleaning, in order to avoid possible damage to the cargo seals?
Stainless steel and live steam are incompatible and contact must therefore be avoided.
What is the particular risk in filling the cofferdam on an older, open loop hydraulic system?
The lack of a feed pump to maintain pressure when the cargo system is not in use can lead to contamination of the hydraulic oil.
The presence of a feed pump to boost the hydraulic oil pressure can lead to contamination of the liquid in the cofferdam.
Failure to apply additional purging checks with pumps in such a system can result in undetected contamination of the cargo.
How do Framo recommend that a number of cargo pumps are run, when required to discharge a homogenous cargo up a common line?
Run a higher, yet practical number of pumps in parallel at reduced hydraulic pressure, rather than a smaller number of pumps at maximum hydraulic pressure.
Run a smaller, yet practical number of pumps in parallel at maximum hydraulic pressure, rather than a higher number of pumps at reduced hydraulic pressure.
When running at full rate, what should be the balance between the hydraulic system pressure and the hydraulic pressure at the pumps?
The system pressure should be no more, than 20 bar above the highest pump pressure.
The system pressure must be exactly the same as the highest consumer pressure.
The system regulator automatically adjusts the balance to the maximum discharge performance.
The hydraulic system pressure should be set to the combined total requirement of all the pumps that are to be run in the current operation.
In which direction is the local control valve on the top cover plate of the cargo pump turned to open it?
What piece of portable equipment is designed to safely release any excess pressure before a blowing hose is disconnected?
Which parts of the pump are especially liable to damage from Phosphoric Acid sediment?
Which of these functions is performed by a Jockey pump in an open loop hydraulic system?
When a number of cargo pumps are required to discharge a homogenous cargo up a common line, how do Framo recommend they are run?
Run a higher, yet practical number of pumps in parallel at reduced hydraulic pressure, rather than a smaller number of pumps at maximum hydraulic pressure.
Run a smaller, yet practical number of pumps at maximum hydraulic pressure, rather than a higher number of pumps at reduced hydraulic pressure.
After blowing lines to shore and closing the manifold valve, what is it recommended to do before stripping?
Relieve any residual pressure in the deck cargo line.
Close the shore manifold valve.
Mark the line blowing entry on the Ship/Shore Safety Checklist.
Which two items of equipment, located in the hydraulic control room, should be checked as running prior to starting discharge operations?
Phosphoric Acid sediment can damage which of the following parts of a cargo pump in particular?
The cofferdam purge pipe flange gasket.
Which of the following cargoes is the most corrosive towards stainless steel?
Methyl Methacrylate Monomer.
When using the local control valve on the top cover plate to operate the cargo pump, in what position should the control handle on the Framo control panel be?
It doesn’t matter when the local control valve is being used.
When preparing for the carriage of fuel oil, which of the following should be added to the pump cofferdam?
5-10 litres of diesel oil.
5-10 litres of fresh water.
35 litres of di-octyl phthalate.
35 litres of hot fresh water.
Which two items from the list below must you consider before opening a lid to check visually if the sump is empty?
What is the purpose of the cofferdam space?
It forms a small void space between the hydraulic oil system and the cargo, capable of being checked at intervals for any possible leakage from either side.
It provides a solid barrier between the hydraulic oil system and the cargo, thereby preventing any possible leakage between the two.
It is an auxiliary system built into the cargo pump for the purposes of cleaning the mechanical seals.
What procedure must be carried out after cargo discharge and stripping are completed?
Record the running hours in the Cargo Log Book.
Notify the Chief Engineer.
Remove the plug from manifold valve casing.
Why is it necessary to use hot water in the cofferdam when carrying Phenol?
Due to the high melting point of Phenol.
Due to the low temperature of the hydraulic oil.
Because Phenol is reactive with cold water.
Because the Code of Carriage of Dangerous Liquid Chemicals (1987) requires that hot water must be used.
How might a tank be tested during tank cleaning to check that all acid residues have been removed?
The discharged washing water can be tested with litmus paper.
The atmosphere can be tested for chlorine content.
The atmosphere can be tested for hydrocarbon content.
The discharged washing water can be tested with carbon paper.
What is the standard opening time for an actuator controlled cargo line valve?
Approximately 20 seconds.
What is the term applied to the formation and collapse of bubbles around the impeller, creating a partial vacuum, causing the pump to surge and heat to be generated, resulting from uncontrolled running to the pump with cargoes such as latex or molasses?
What maintenance procedure must be carried after cargo discharge and stripping operations are complete?
Purge the pump cofferdams.
Test the cargo valves for full and correct operations.
Pressure test the cargo lines.
Remove the plugs and open the valves on the stripping lines.
Which of the following factors is considered an advantage of a closed loop hydraulic system?
The size of the hydraulic tank.
The air release procedure.
The number of components.
What is the recommended supply pressure to have available for cleaning the deck cargo line?
Which of the following precautions would be carried out in preparation for the loading of a cargo of toluene di-isocyanate?
Filling the cofferdam with di-octyl phthalate.
Filling the cofferdam with fresh water.
Plugging the cofferdam check pipe inlet and purging pipe outlet.
Replacing the cargo seals in the pump.
When controlling the pump using the local control valve on the top cover plate, in what position should the control handle on the Framo control panel be?
It doesn’t matter when the local control valve is being used.
Select two reasons from the list below as to why, with certain cargoes, it is advantageous to fill the cofferdam with liquid:
Which direction would you turn the local control valve on the top cover plate of the cargo pump to open it?
During start-up of loading, which of the following precautionary measures will avoid pressure shocks in the pipeline system? Select all applicable answers:
What is the backstop unit?
A device that prevents the impeller running in reverse when loading is carried out through the pump.
A non-return valve on the hydraulic oil supply line.
A tool, which provides easy access to the cargo seals during maintenance.
A device, that allows the impeller to be rotated manually from deck to clear a blockage.
Contaminated hydraulic oil can lead to which of the following?
Which of the following are functions of the double cargo lip seal?
Which of the following are typical signs of worn wear rings? Select all applicable answers:
What term is applied to the removal of final cargo residues from a tank and its associated piping?
After purging a pump, from where will any liquid resulting from leakage be collected?
The exhaust trap drain valve.
The air/nitrogen outlet tap.
When discharging a number of tanks simultaneously, how would you adjust the rate from an individual tank?
By throttling the cargo pump discharge valve.
By regulating the main system hydraulic pressure.
By adjusting the individual pump hydraulic pressure.
By throttling the manifold valve.
What name is given to the process by which the final residues of cargo are removed from a tank and its associated piping?
Under which of the following circumstances should the emergency stop be activated? Select all applicable answers:
Which of the following is the only reason for closing the service valves on the hydraulic supply lines?
For maintenance work on the pump or lines.
When no cargo operations are taking place.
At the start-up of cargo operations.
On completion of cargo operations.
Where would you find the results of a vessels stripping test?
The Certificate of Registry.
The Procedures and Arrangements Manual.
The latest shipyard report.
Which of the following factors are considered the advantages of an open loop hydraulic system? Select all applicable answers:
Which of the following mixtures should not be stored in stainless steel tanks? Select all applicable answers:
Under what circumstances should the service valves on the hydraulic supply lines be closed?
For maintenance work on the pump or lines.
When no cargo operations are taking place.
At the start-up of cargo operations.
On completion of cargo operations.
At what opening pressure is the relief valve set?
When preparing for the carriage of molasses, which of the following liquids is filled to the pump cofferdam?
Rotation of the impeller causes the liquid to flow towards the periphery of the pump casing through which of the following forces:
How are the bearings on the shaft lubricated?
By the low pressure hydraulic return oil.
By the high pressure hydraulic oil supply.
By an oil sump in the cargo pump casing.
By grease added manually during pump overhaul.
What is the purpose of wear rings?
To hold the base of the cargo pump firmly in place and limit any vibration.
To hold the mechanical oil seal position at the base of the cofferdam.
To keep the cargo from escaping back into the cargo tank and direct it instead through the discharge line.
To reverse the direction of flow within the volute casing.
Why are wear rings fitted around the base of a pump?
To prevent cargo from escaping back into the cargo tank and direct it instead through the discharge line.
To hold the base of the cargo pump securely in place and prevent vibration.
To hold the cargo seal in position at the base of the cofferdam.
To reverse the direction of flow within the volute casing.
When preparing for the carriage of fuel oil, which of the following liquids should be added to the pump cofferdam?
In order to prevent damage to a stainless steel tank, what will be required after salt water washing?
Testing the bulkhead with reagent chemical.
Recirculation with an acid-based cleaning chemical.
Purging the pump cofferdam.
Rinsing down with fresh water.
If live stream is applied during tank cleaning, what is the maximum recommended duration, in order to avoid possible damage to the cargo seals?
What is parallel pumping?
Running a number of cargo pumps together to discharge a homogenous cargo from several tanks simultaneously up a common line.
Running adjacent cargo pumps at the same time.
Starting an even number of cargo pumps in pairs and operating them at the same discharge pressure.
Adjusting a number of cargo pumps so that the tanks complete discharge at the same time.
Which of the following substances can easily damage stainless steel surfaces during short-term exposure, if improperly handled? Select all applicable answers:
Where is the mechanical seal located?
Between the low pressure return oil side and the cofferdam.
Between the high pressure supply oil and the cofferdam.
Between the cofferdam and the cargo.
Between the impeller and the pump shaft.
Cargo leakage found in the cofferdam can have come from which of the following places? Select all applicable answers:
In which of the following ways does purging assist the ship’s personnel? Select all applicable answers:
Hydraulic oil leakage found in the cofferdam can have come from which of the following places? Select all applicable answers:
Why is a closed loop hydraulic system considered safer in an operation, which involves filling the pump cofferdam with liquid?
Because the feed pump maintains a small positive pressure in the circuit when the cargo system is not in use, thereby avoiding the possibility of oil contamination.
Because the feed pump absorbs any excess pressure in the hydraulic system, thereby avoiding the possibility of mechanical seal failure.
Because the header tank in a closed loop system is of a smaller capacity and therefore exerts a lower gravitational pressure on the system.
Because the pipework in a closed loop circuit is of a smaller diameter and it therefore runs at a lower system pressure.
Which of the following statements is a definition of parallel pumping?
Running a number of cargo pumps together to discharge a homogenous cargo from several tanks simultaneously up a common line.
Running adjacent cargo pumps at the same time.
Adjusting the hydraulic pressures of a number of cargo pumps, so that the tanks complete discharge at the same time.
Running a group of cargo pumps together by running each up independently, but to the same hydraulic pressure.
When preparing for the carriage of isocyanates, what substance is the pump cofferdam filled with?
Why is it necessary to use specifically hot water in the cofferdam when carrying Phenol?
Due to the high melting point of Phenol.
Due to the high temperature of the hydraulic oil.
Because Phenol is reactive with cold water.
Because MARPOL 73/78 Regulations stipulate that hot water used.
If four tanks, of identical size and filled to the same ullage, are to be discharged at the same time up a common shore line, what is the recommended procedure to follow when controlling the overall discharge rate?
Keep the main hydraulic system pressure at maximum and regulate individual pump pressures as required.
Keep all the pump controllers in the maximum position and regulate the main hydraulic system pressure.
Keep the main hydraulic pressure at maximum and run all cargo pumps at 35 bar less than the main setting.
Neglecting purging can result in which of the following?
Missing scheduled maintenance.
Leakage at the exhaust trap drain valve.
Difficulty in connecting the air or nitrogen purging line.
Which of the features below is an indication that a pump is losing suction? Select all applicable answers: